BENDIX SD-13-4958 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Modulátor BENDIX SD-13-4958. BENDIX SD-13-4958 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1
Supply Port
(Casting has
“1, SUP”)
Exhaust Port
(Body has
“3, EXH”)
Supply
Port
(Casting has
“1, SUP”)
Exhaust Port
(Body has “3, EXH”)
Electrical
Connector
Mounting Holes
(.33" Diameter
Through Body)
Alternate Push-to-
Connect Version,
Showing Optional
Packard Connector
Electrical
Connector
Delivery Port
(Casting has
“2, DEL”)
Bendix
®
M-40HF
Modulator
Bendix
®
M-40QR
Modulator
SD-13-4958
DESCRIPTION
The Bendix
®
M-40QR
(quick release) and M-40HF
(high
ow) pressure modulator valves (PMVs) are high-capacity,
on/off air valves that incorporate a pair of electrical
solenoids for control. See Figure 1. The solenoids provide
the electro-pneumatic interface between the vehicles
electronic control system and the air brake system. For
example, the PMV is used to control the braking function
of service actuators during antilock activity.
The modulator consists of a die cast metal and plastic body
that houses one normally-open solenoid, one normally-
closed solenoid, and an inlet and exhaust diaphragm
valve. A three-pin weather-resistant electrical connector
is an integral part of the modulator solenoid assembly
and delivers the vehicle controllers commands to the
modulator. Two mounting holes are provided for frame or
crossmember mounting of the valve.
The Bendix M-40QR modulator is the direct replacement
for the Bendix M-32QR modulator (See Figure 2). The
Bendix M-40QR modulator has a bias valve to provide an
internal quick-release function.
Bendix
®
M-40QR
and M-40HF
Pressure Modulator Valves
FIGURE 1 - M-40QR
AND M-40HF
PRESSURE MODULATOR VALVES
The supply, delivery and exhaust ports on the Bendix M-40
modulators have embossed identication codes.
Port ID
Air Hose
Connection
Function
1, SUP Supply
Air enters from a valve (typically
foot, relay or quick release).
2, DEL Delivery
Air is delivered to the service
actuators.
3, EXH Exhaust Air is vented to the atmosphere.
FIGURE 3 - PORT DESIGNATION AND FUNCTION
APPLICATIONS
Bendix M-40 modulators may be used for various purposes
on a vehicle including ABS and stability interventions. In
applications using these PMVs, an external quick release
valve may also be required, depending on the system
design. Where the modulator is used for individual wheel
control applications, it is typically the last control valve
through which air passes on its way to the service brake
actuator. See Figure 4 for a typical system schematic.
Previous Model
M-32
Modulators
Bendix M-32QR
(left) and M-32
(right) Modulators
FIGURE 2 - M-32
MODULATORS
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - Pressure Modulator Valves

1Supply Port(Casting has“1, SUP”)Exhaust Port(Body has“3, EXH”)Supply Port(Casting has “1, SUP”)Exhaust Port(Body has “3, EXH”)Electrical Connector Mo

Strany 2 - GENERAL SAFETY GUIDELINES

2GENERAL SAFETY GUIDELINESWARNING! PLEASE READ AND FOLLOW THESE INSTRUCTIONSTO AVOID PERSONAL INJURY OR DEATH:When working on or around a vehicle, the

Strany 3

3PRESSURE MODULATOR VALVE (PMV) AND TRACTION CONTROL VALVE (TCV) CHUFF TESTA wiring harness connects the vehicle modulators to the controller. The AB

Strany 4 - OPERATION

4ANTILOCK OPERATIONGENERALSee Figure 6. The rst four rows of this table show normal vehicle braking where the PMV does not intervene. In th

Strany 5 - PREVENTIVE MAINTENANCE

5ANTILOCK APPLY MODEIf a service brake application is made and the antilock system detects an impending wheel lockup, the antilock controller will mak

Strany 6 - ELECTRICAL TESTS

6LEAKAGE TEST1. Park the vehicle on a level surface and block or chock the wheels. Release the parking brakes and build the air system to full pressu

Strany 7 - MODULATOR REMOVAL

7FIGURE 9 - BENDIX® M-40QR™ AND M-40HF™ MODULATORS DIN SYMBOLMODULATOR REMOVAL1. Locate the modulator that will be replaced and clean the exterior.2.

Strany 8 - GLOSSARY

8SD-13-4958 © 2014 Bendix Commercial Vehicle Systems LLC, a member of the Knorr-Bremse Group. 12/14. All Rights Reserved.BW2899Log-on and Learn fro

Komentáře k této Příručce

Žádné komentáře