
Using the Gen 4 & 5 Diagnostic Options
NEXIQ Brake-Link™ Bendix
®
& Eaton
®
ABS Applications 87
3 Brake-Link™ presents the
Gen 4/5 Diagnostic
Options
menu; use the
and keys to scroll to
TESTS
and press .
4 Brake-Link™ displays the
Tests Menu
; use the and keys to
position the cursor on
TEST WARNING LAMP
and press .
Note:
If wheel speeds are greater than 5 kph, Brake-Link™ dis-
plays a message indicating that the test cannot be performed.
5 Brake-Link™ blinks the lamp 4 times; while performing the test, it dis-
plays the following message.
Once it finishes the test, it displays TEST IS COMPLETED. Press
to return to the
Tests Menu
.
6 Press to return to the main menu or to return to the
Select Application
screen.
Self-Configuration
Generation 4 and 5 controllers can auto-detect ABS components and automat-
ically adjust the current configuration. Use Brake-Link™ to initiate this proce-
dure.
Initiate procedure via menu navigation.
ECU INFORMATION
FAULTS
DATA LIST
TESTS
ACTIVATING
WARNING LAMP
ON AND OFF...
The ECU must recognize all ABS components. To avoid improper re-
configuration and/or damaging the ECU, be sure all system peripherals
(i.e., modulators, sensors, etc.) are properly installed/connected before
initiating self-configuration.
Komentáře k této Příručce