Section 9: Air Brake System Troubleshooting Tests
Air Brake System Troubleshooting Tests
Please follow all standard safety precautions, including, but not limited to,
the general precautions listed on page 4 of this handbook.
TEST ONE
Governor cut-out / Low pressure warning / Pressure build-up
Vehicle parked, wheels chocked
OK
Not
OK
1. Drain all the reservoirs to 0 psi.
2.
Start the engine and run at fast idle. The low pressure warning should be on. Note: on vehicles equipped
with ABS, the warning lamp will also come on momentarily when the ignition is turned on. On some
systems, such as the AD-IS
®
dryer system (illustrated), reservoirs may not fi ll simultaneously and one
reservoir may fi ll to 110 psi before the other starts to fi ll.
3. Low pressure warning; dash warning lamp should go off above 60 psi.
4. Build up time; pressure should build from 85-100 psi within 40 seconds.
5. Governor cut-out; cuts out at the correct pressure, usually 125-135 psi.
6.
Governor cut-in; reduce the service air pressure to governor cut-in. The difference between cut-in and cut-
out pressure must not exceed 30 psi.
1. Check the warning lamp wiring.
2. Check the warning lamp bulb.
3. Repair or replace the buzzer, bulb or low pressure warning
switch(es).
If the governor cut-out is higher or lower than specifi ed by
the vehicle manual:
1. Repair, replace or adjust the governor as necessary after
ensuring the compressor unloader mechanism is operating
correctly.
If the low pressure warning occurs below 60 psi:
1. Check the dash gauge with test gauge known to be accurate.
2. Repair or replace the faulty low pressure indicator switch.
If the compressor build up time exceeds 40 seconds or is
considerably greater than the permanent record fi gure:
1. Examine the compressor air inlet fi lter and inlet line checking
for restrictions, damage or wear. Clean or replace the fi lter or
inlet line as necessary.
2. Check the compressor discharge port and line for excessive
carbon. Clean or replace the discharge line as necessary. If
there is carbon, fi nd the cause of the excessive heat.
3. With the system fully charged and governor in the unloaded
mode, listen at the compressor inlet for leakage. If leakage
can be heard, remove the unloaders and repair or replace as
necessary.
Retest to verify proper operation of all items repaired or
replaced.
Make all the necessary repairs before proceeding to test 2; see checklist 1 for common corrections.
CHECKLIST ONE
If the low pressure warning lamp or buzzer doesn’t come on: